Data record gloss.absence-of-voltage-test.osha1910-269.verification-before-work
Verified 2026-10-28 Confidence: High
Under 29 CFR 1910.269, the authorized employee verifies that isolation and de-energizing have been accomplished before starting work on locked-out or tagged-out machines or equipment, and where normally energized parts will be exposed to contact a test is performed to confirm that those parts are de-energized. The step is stated in paragraph (d)(6)(vii) for electric power generation installations.
| Step | Item | Detail |
|---|---|---|
| Source | 29 CFR 1910.269 | Regulation, clause (d)(6)(vii) |
| Data record | gloss.absence-of-voltage-test.osha1910-269.verification-before-work | Verified 2026-10-28 |
| Entry | Absence of voltage test | No revisions |
- Subject
- Absence of voltage test (Glossary)
- Kind
- Standard scope
- Source
- 29 CFR 1910.269, current edition, clause (d)(6)(vii), 1910.269 - Electric power generation, transmission, and distribution (with Appendices A to G; Appendix B, Working on Exposed Energized Parts), OSHA. Regulation text. Agency copy of 29 CFR 1910.269
- Also stated in
- 29 CFR 1910.269, paragraph (d)(6)(vii) (eCFR current as of 2026-10-26).
Read the reference passage
"Before starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergizing of the machine or equipment have been accomplished. If normally energized parts will be exposed to contact by an employee while the machine or equipment is deenergized, a test shall be performed to ensure that these parts are deenergized."
29 CFR 1910.269, paragraph (d)(6)(vii), eCFR current as of 2026-10-26. Agency copy of 29 CFR 1910.269
The current standard governs; this passage is a public-domain description of the practice dated eCFR current as of 2026-10-26.
- 29 CFR 1910.269, paragraph (d)(6)(vii) (eCFR current as of 2026-10-26).
- Beside
- gloss.absence-of-voltage-test.nfpa70e.step-7; std.nfpa-70e.structure.120-6-7-absence-of-voltage
History
| Date | Change |
|---|---|
| 2026-10-28 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record gloss.absence-of-voltage-test.osha1910-269.verification-before-work." Arc Flash Reference. 2026-10-28. https://www.arcflashreference.com/data/gloss.absence-of-voltage-test.osha1910-269.verification-before-work/.
Arc Flash Reference, Data record gloss.absence-of-voltage-test.osha1910-269.verification-before-work (Oct. 28, 2026), https://www.arcflashreference.com/data/gloss.absence-of-voltage-test.osha1910-269.verification-before-work/.
@misc{etr-data-gloss-absence-of-voltage-test-osha1910-269-verification-before-work,
title = {Data record gloss.absence-of-voltage-test.osha1910-269.verification-before-work},
howpublished = {\url{https://www.arcflashreference.com/data/gloss.absence-of-voltage-test.osha1910-269.verification-before-work/}},
organization = {Arc Flash Reference},
publisher = {Arc Flash Reference},
year = {2026},
note = {last substantive change 2026-10-28}
}{{cite web |title=Data record gloss.absence-of-voltage-test.osha1910-269.verification-before-work |website=Arc Flash Reference |publisher=Arc Flash Reference |url=https://www.arcflashreference.com/data/gloss.absence-of-voltage-test.osha1910-269.verification-before-work/ |date=2026-10-28 |access-date=}}